| Cecomp New Product Announcements |
| Model |
Features |
Product |
Specifications |
Intrinsically Safe
Battery Powered Digital Pressure Gauges
DPG2000B series
BL = backlit display
FM approved Class I,
Division 1, Groups, A, B, C, D
|
- Battery life to 1000 hrs
- BL red LED display backlight battery life 150 to 1000 hrs
- Externally accessible zero and span potentiometers
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- All metal housing
- Optional ±0.1% accuracy in most ranges
- Optional top gauge port
- Includes 2 AAA batteries
- 7-10 day typical lead time
- 1 year warranty
|

DPG2000B
|
- Vacuum to 2000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2, inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar, kPa, MPa, atm, kg/cm2, custom
- Choose auto shutoff time
- -5 five minutes
- -10 ten minutes
- -30 thirty minutes
|
Digi-Max+
Battery Powered Digital Pressure Gauges with
Programmable Min/Max
Push Button Zero
Keypad Selectable Units
Keypad Selectable Shutoff
F22B series
BL = backlit display
N = NEMA 4X
|
- Capture minimum and/or maximum readings
- Able to retain min/max at power off
- Selectable auto shutoff time
- Pushbutton zero at power-up (gauge reference ranges only)
- Pass code protected setup and calibration
- 4 digit display
- Battery life to 2000 hrs
- BL red LED display backlight battery life 150 to 1500 hrs
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- Includes 2 AA batteries
- 7-10 day typical lead time
- 1 year warranty
|
F22B
F22BN |
- Vacuum to 5000 psi ranges
- Absolute reference available
- Slectable engineering units available: psi, inHg, oz/in2, inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar, kPa, MPa, atm, kg/cm2 depending on range
|
T16B Series
ThermoPro®
Battery Powered RTD Temperature Indicator
|
- 0.1 degree display resolution
- Precision RTD element
- NEMA 4X housing
- Powered by two AA batteries (included)
- 316 stainless steel probe
- 1/2" NPT fitting for standard thermowells
- Spring-loaded probe available for use with thermowells
|
|
Specify RTD length and fixed or spring-loaded RTD
Temperature range
–58.0°F to 392.0°F or
–50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
|
T16ADA Series
ThermoPro®
Indicating RTDTemperature Alarm
|
- User-programmable alarm relays
- 0.1 degree display resolution
- Precision RTD element
- NEMA 4X housing
- Powered by 8-32 VDC, 10-32 VAC
- 316 stainless steel probe
- 1/2" NPT fitting for standard thermowells
- Spring-loaded probe for use with thermowells
|
|
Specify RTD length and fixed or spring-loaded RTD
Temperature range
–58.0°F to 392.0°F or
–50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
Output
2 SPDT relays,
1 A @ 24 VDC,
0.5 A @ 115 VAC,
Non-inductive,
Fully programmable
|